Psu0043, Psu0044 – Dell PowerEdge VRTX User Manual

Page 544

Advertising
background image

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

Trap/EventID

2185

LCD Message

Output over current fault detected on PSU <number>. Check PSU.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0043

Message

An output under current fault detected on power supply

arg1

.

Arguments

arg1 =

number

Detailed
Description

None

Recommended
Response Action

1) Remove the power supply input cord and then remove power supply. 2) Re-install the power
supply and then re-install the power supply cord. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

Trap/EventID

2185

LCD Message

Output under current fault detected on PSU <number>. Check PSU.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0044

Message

Cannot obtain status information from power supply

arg1

.

Arguments

arg1 =

number

Detailed
Description

The power supply is operating but the system cannot get status information.

544