Description

A disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail
in the near future.

Recommended
Response Action

Replace the disk that has received the SMART alert. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a physical
disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may
cause data loss.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR24

Message

Failure prediction threshold exceeded on

arg1

due to test. No action needed.

Arguments

arg1 =

PD Name

Detailed
Description

A disk has received a SMART alert (predictive failure) due to test conditions.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR25

Message

arg1

dead segments are removed.