Pdr20, Pdr21 – Dell PowerEdge VRTX User Manual

Page 437

Advertising
background image

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR20

Message

SMART configuration change for

arg1

.

Arguments

arg1 =

PD Name

Detailed
Description

A disk has received a SMART alert (predictive failure) after a configuration change. The disk is
likely to fail in the near future.

Recommended
Response Action

Replace the disk that has received the SMART alert. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a physical
disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may
cause data loss.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 1 (Critical)

Trap/EventID

4345

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR21

Message

SMART warning for

arg1

Arguments

arg1 =

PD Name

Detailed
Description

A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near
future.

Recommended
Response Action

Replace the disk that has received the SMART alert. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a physical
disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may
cause data loss.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)