Enc31, Enc32 – Dell PowerEdge VRTX User Manual

Page 227

Advertising
background image

SubCategory

ENC = Storage Enclosr

Severity

Severity 3 (Informational)

Trap/EventID

4339

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC31

Message

Firmware download on

arg1

has failed.

Arguments

arg1 =

Enclosure Name

Detailed
Description

The system was unable to download firmware to the enclosure. The controller may have lost
communication with the enclosure. There may have been problems with the data transfer or
the download media may be corrupt.

Recommended
Response Action

Attempt to download the enclosure firmware again. If problems continue, verify that the
controller can communicate with the enclosure. Make sure that the enclosure is powered ON.
Refer to the storage hardware documentation for information on checking the cables.

Category

Storage

SubCategory

ENC = Storage Enclosr

Severity

Severity 2 (Warning)

Trap/EventID

4338

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC32

Message

Storage Enclosure Processor (SEP) for

arg1

has been rebooted.

Arguments

arg1 =

Enclosure Name

Detailed
Description

The SEP has been rebooted as part of the firmware download operation and will be unavailable
until the operation completes.