Pdr31, Pdr32 – Dell PowerEdge VRTX User Manual

Page 443

Advertising
background image

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR31

Message

A global hot spare has been removed.

arg1

Arguments

arg1 =

PD Name

Detailed
Description

The controller cannot to communicate with a disk that is assigned as a global hot spare. The
disk either failed or was removed. There may also be a bad or loose cable.

Recommended
Response Action

Verify that the disk is healthy and installed. Check the cables. Refer to the product
documentation and see the Cables Attached Correctly section for more information on
checking the cables. If necessary, replace the disk and reassign the global hot spare.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 3 (Informational)

Trap/EventID

4347

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR32

Message

A dedicated hot spare failed.

arg1

Arguments

arg1 =

PD Name

Detailed
Description

The controller cannot to communicate with a disk that is assigned as a global hot spare. The
disk either failed or was removed. There may also be a bad or loose cable.

Recommended
Response Action

Verify that the disk is healthy and installed. Check the cables. Refer to the product
documentation and see the Cables Attached Correctly section for more information on
checking the cables. If necessary, replace the disk and reassign the global hot spare.

443