Pdr27, Pdr28 – Dell PowerEdge VRTX User Manual

Page 441

Advertising
background image

PDR27

Message

Dedicated hot spare assigned to

arg1

.

Arguments

arg1 =

PD Name

Detailed
Description

A user assigned a physical disk as a dedicated hot spare to a virtual disk. See Protecting Your
Virtual Disk with a Hot Spare for more information. This alert is provided for informational
purposes.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 3 (Informational)

Trap/EventID

4347

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR28

Message

Dedicated hot spare unassigned from

arg1

.

Arguments

arg1 =

PD Name

Detailed
Description

A physical disk that was assigned as a hot spare has been unassigned and is no longer
functioning as a hot spare. The physical disk was unassigned by a user or automatically
unassigned by Storage Management. Storage Management unassigns hot spares that have
been used to rebuild data. Once data is rebuilt onto the hot spare, the hot spare becomes a
member of the virtual disk and is no longer assigned as a hot spare. Assign a new hot spare to
maintain data protection in this situation.

Recommended
Response Action

Although this alert is provided for informational purposes, you may need to assign a new hot
spare to the virtual disk. Refer to product documentation and see the section Protecting Your
Virtual Disk with a Hot Spare for more information.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 3 (Informational)

Trap/EventID

4347

441