Ctl74, Ctl75 – Dell PowerEdge VRTX User Manual

Page 199

Advertising
background image

Trap/EventID

4331

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL74

Message

Preserved cache detected on

arg1

.

Arguments

arg1 =

controller name

Detailed
Description

The controller has preserved data in the cache from a virtual disk, which it can no longer
locate. No data loss has occurred as the controller is saving these operations in its cache.

Recommended
Response Action

Check for the existence of a foreign configuration and import if any. Check that enclosures are
cabled correctly.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 2 (Warning)

Trap/EventID

4330

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL75

Message

Preserved cache discarded on

arg1

.

Arguments

arg1 =

controller name

Detailed
Description

The controller cache was discarded by the user. Data may have been lost or corrupted.

Recommended
Response Action

If data was corrupted or lost, restore the data to the disk from a backup copy.

Category

Storage

SubCategory

CTL = Storage Contr

199