Pwr8552, Pwr8554 – Dell PowerEdge VRTX User Manual

Page 573

Advertising
background image

SubCategory

PWR = Power Usage

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8552

Message

Chassis Management Controller is unable to turn on

arg1

-

arg2

because of insufficient power.

Arguments

arg1 =

component name

arg2 =

component id

Detailed
Description

There is insufficient power for the component identified in the message to turn on.

Recommended
Response Action

Make sure there is enough power supply to distribute power. Using the CMC Web UI, go to
Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For
Allocation field view the available power. To add more power, insert more PSUs or remove
unused components from the chassis. Contact your service provider for information on the
power required for the component identified in the message.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

Trap/EventID

8418

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8554

Message

Chassis Management Controller is unable to send power allocation information to

arg1

-

arg2

at

priority

arg3

.

Arguments

arg1 =

component name

arg2 =

component id

573