Vlt0205, Vlt0206 – Dell PowerEdge VRTX User Manual

Page 911

Advertising
background image

Severity

Severity 1 (Critical)

Trap/EventID

2169

LCD Message

System board <name> voltage is outside of range. Contact support

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

VLT0205

Message

The system board

arg1

voltage is within range.

Arguments

arg1 =

name

Detailed
Description

None

Recommended
Response Action

No response action is required.

Category

System Health

SubCategory

VLT = Voltage

Severity

Severity 3 (Informational)

Trap/EventID

2171

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

VLT0206

Message

The memory module

arg1arg2

voltage is less than the lower warning threshold.

Arguments

arg1 =

number

arg2 =

name

Detailed
Description

System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.

Recommended
Response Action

1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the
problem persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.

911

Advertising