Iov1002, Iov1003 – Dell PowerEdge VRTX User Manual

Page 312

Advertising
background image

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

IOV1002

Message

The operation was not successful.

Detailed
Description

The operation did not complete successfully due to an exception from the instrumentation
layer.

Recommended
Response Action

Retry the operation. If the issue persists, reset CMC and retry the operation when the CMC has
completed restarting. The CMC may take 2 to 3 minutes to complete restarting.

Category

Configuration

SubCategory

IOV = IO Virtualization

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

IOV1003

Message

Missing required parameter

arg1

.

Arguments

arg1 =

parameter name

Detailed
Description

One or more parameters identified in the message required for the method are missing.

Recommended
Response Action

Refer to the Dell Chassis PCI Management Profile document and provide the required
parameter.

Category

Configuration

SubCategory

IOV = IO Virtualization

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None