Cmc8547, Cmc8548 – Dell PowerEdge VRTX User Manual

Page 126

Advertising
background image

Category

Audit

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8547

Message

Missing kernel module

arg1

. Failover condition detected

Arguments

arg1 =

module name

Detailed
Description

A firmware error occurred causing the failover. If this condition continues, a failover will result.
If multiple failovers occur, contact Service.

Recommended
Response Action

No response action is required. If the issue persists, contact your service provider.

Category

Audit

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8548

Message

Unable to communicate with peer CMC.

Detailed
Description

The local CMC has lost network connection with peer CMC for more than the timeout duration.
The timeout duration is 25 seconds for primary CMC and five seconds for secondary CMC.
After detecting the error, failover is performed if secondary CMC is available, otherwise CMC is
reset.

Recommended
Response Action

Make sure that the network cable is connected to the primary CMC. A Link loss was detected.

126