Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

SWC8522

Message

Chassis Group Leader update of member

arg1

configuration successful.

Arguments

arg1 =

member id

Detailed
Description

Successfully completed a configuration sync with the member identified in the message.

Recommended
Response Action

No response action required.

Category

Audit

SubCategory

SWC = Software Config

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

SWC8523

Message

Unable to complete Chassis Group Leader update of member

arg1

.

Arguments

arg1 =

DNS or IP address

Detailed
Description

Unable to complete a configuration sync with the member identified in the message.

Recommended
Response Action

Check the communications between the Chassis Group Leader and the member. Run the
RACADM command "racadm ping <DNS or IP address> " to check the communications. If the
communications are not functional, resolve the communications issue. If the communications
are functional, remove the member from the group and re-add the member. If the issue
persists, contact your service provider.

Category

Audit

SubCategory

SWC = Software Config

Severity

Severity 1 (Critical)

769