Recommended
Response Action

Check for factors that may cause overheating. For example, verify that the enclosure fan is
working. You should also check the thermostat settings and examine whether the enclosure is
located near a heat source. Make sure the enclosure has enough ventilation and that the room
temperature is not too hot. Refer to the enclosure documentation for more diagnostic
information.

Category

Storage

SubCategory

TMP = Temperature

Severity

Severity 1 (Critical)

Trap/EventID

4209

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

TMP1003

Message

arg1

has crossed the minimum failure threshold.

Arguments

arg1 =

tempsensor name

Detailed
Description

The enclosure is too cold.

Recommended
Response Action

Check whether the thermostat setting is too low and whether the room temperature is too cool.

Category

Storage

SubCategory

TMP = Temperature

Severity

Severity 1 (Critical)

Trap/EventID

4209

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

TMP5

Message

The temperature probe maximum warning value was changed on

arg1

.