Ctl50, Ctl51 – Dell PowerEdge VRTX User Manual

Page 186

Advertising
background image

Recommended
Response Action

No response action is required as the controller is taking the required corrective action.
However, If this message is generated often (such as during each reboot), then replace the
controller.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 2 (Warning)

Trap/EventID

4330

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL50

Message

The

arg1

NVRAM has corrupt data.

Arguments

arg1 =

Controller name

Detailed
Description

The NVRAM has corrupt data. The controller is unable to correct the situation.

Recommended
Response Action

Replace the controller.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 2 (Warning)

Trap/EventID

4330

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL51

Message

arg1

SAS port report:

arg2

Arguments

arg1 =

Controller name

arg2 =

message

186