Pwr8584, Pwr8585 – Dell PowerEdge VRTX User Manual

Page 589

Advertising
background image

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PWR8584

Message

Chassis Management Controller is unable to turn on server-

arg1

because the power supply

redundancy is lost and Performance Over Power Redundancy feature is disabled and the
power required is less than the available power.

Arguments

arg1 =

slot number

Detailed
Description

If power redundancy is lost and the server Performance Over Power Redundancy feature is
disabled, the server turn-on will not be allowed.

Recommended
Response Action

To enable the server to be turned-on, on the Power Configuration page in the Web UI, enable
the server Performance Over Power Redundancy option . Using the RACADM utility, tun the
following command "racadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 1". Then retry the oepration.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PWR8585

Message

Chassis Management Controller granted the power required to turn on server-

arg1

.

Arguments

arg1 =

slot number

Detailed
Description

Chassis Management Controller granted the power required to turn on the server identified in
the message.

589

Advertising