Psu0031, Psu0046 – Dell PowerEdge VRTX User Manual

Page 528

Advertising
background image

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PSU0031

Message

Cannot communicate with power supply

arg1

.

Arguments

arg1 =

number

Detailed
Description

The power supply may operate, however power supply monitoring will be degraded. System
performance may be degraded.

Recommended
Response Action

Remove and re-install the power supply. If the issue persists, contact technical support. Refer
to the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

Trap/EventID

2185

LCD Message

Cannot communicate with PSU <number>. Reseat PSU.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0046

Message

Communication has been restored to power supply

arg1

.

Arguments

arg1 =

number

Detailed
Description

None

Recommended
Response Action

No response action is required.

Category

System Health

SubCategory

PSU = Power Supply

528