BOOT Event Messages
BOOT8500
Message
Unable to change the BIOS boot order for the Server
arg1
Arguments
•
arg1 =
slot number
Detailed
Description
Unable to change the BIOS boot order for the server because of a broken communication
between the CMC and iDRAC, or iDRAC is rebooting.
Recommended
Response Action
Reset iDRAC or wait until iDRAC reboots, and retry the operation.
Category
Configuration
SubCategory
BOOT = BOOT Control
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE