Sel1501, Sel1502 – Dell PowerEdge VRTX User Manual

Page 708

Advertising
background image

Detailed
Description

None

Recommended
Response Action

No response action is required.

Category

System Health

SubCategory

SEL = Sys Event Log

Severity

Severity 3 (Informational)

Trap/EventID

2379

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

SEL1501

Message

Chassis management controller (CMC) redundancy is lost.

Detailed
Description

An action or failure has taken place that breaks CMC redundancy. This includes loss of
network connection, hardware failures, firmware update, firmware mismatch between CMCs,
CMC reset, and unplugging a CMC.

Recommended
Response Action

Check CMC network cables and network connections. Check that CMC firmware versions
match.

Category

System Health

SubCategory

SEL = Sys Event Log

Severity

Severity 1 (Critical)

Trap/EventID

2377

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

SEL1502

Message

Chassis management controller (CMC) redundancy is degraded.

Detailed
Description

An action or failure has taken place that degrades CMC redundancy. This includes firmware
mismatch between CMCs and a CMC missing SD card.