Pdr5, Pdr6 – Dell PowerEdge VRTX User Manual

Page 429

Advertising
background image

SubCategory

PDR = Physical Disk

Severity

Severity 3 (Informational)

Trap/EventID

4347

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR5

Message

arg1

is removed.

Arguments

arg1 =

PD Name

Detailed
Description

A physical disk has been removed from the disk group. This alert can also be caused by loose
or defective cables or by problems with the enclosure.

Recommended
Response Action

Do one of the following: 1) If a physical disk was removed from the disk group, either replace
the disk or restore the original disk. Identify the disk that was removed by locating the disk that
has a red "X" for its status. 2) Perform a rescan after replacing or restoring the disk. 3) If a disk
was not removed from the disk group, then check for cable problems. Refer to product
documentation for more information on checking the cables. 4) Make sure that the enclosure is
powered on. 5) If the problem persists, check the enclosure documentation for further
diagnostic information.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR6

Message

arg1

is offline.

Arguments

arg1 =

physical disk

429