Ctl61, Ctl62 – Dell PowerEdge VRTX User Manual

Page 192

Advertising
background image

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 3 (Informational)

Trap/EventID

4331

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL61

Message

Physical disks found missing from configuration during boot time on

arg1

.

Arguments

arg1 =

Controller name

Detailed
Description

The controller has detected a change in the storage configuration between since its last shut
down. This can generally happen if some configured physical disks are removed from the
system when the system was shutdown.

Recommended
Response Action

Shut down the system. Re-insert the removed physical disks and re-start the system.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 2 (Warning)

Trap/EventID

4330

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL62

Message

arg1

on

arg2

has missing drives and will go offline at boot.

Arguments

arg1 =

VD names

arg2 =

Controller name

192