Ctl72, Ctl73 – Dell PowerEdge VRTX User Manual

Page 198

Advertising
background image

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL72

Message

The foreign configuration overflow has occurred on

arg1

.

Arguments

arg1 =

Controller name

Detailed
Description

There is too much foreign configuration data to be imported in one attempt.

Recommended
Response Action

Import these foreign configurations in multiple attempts.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 2 (Warning)

Trap/EventID

4330

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL73

Message

Foreign configuration is imported only partially. Some configurations failed to import on

arg1

.

Arguments

arg1 =

Controller name

Detailed
Description

This alert is provided for informational purposes.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 3 (Informational)

198