Description

The Chassis Management Controller is unable to set the administrator role for the iDRAC root
user. This can happen if the communction to the iDRAC from CMC is non-functional or iDRAC is
rebooting.

Recommended
Response Action

If communications with the iDRAC is not functioning, reset the iDRAC and retry the operation
after a few minutes. Run the RACADM command "racadm ping server-<slot number> " to check
the communications. If the communications are not functional, restart the iDRAC by performing
a Virtual Reseat of the server using the RACADM command "racadm racreset -m server-<slot
id>".

Category

Audit

SubCategory

SWC = Software Config

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

SWC8532

Message

Chassis Management Controller is unable to set chassis assigned QuickDeploly IP addresses
because the starting IP address cannot accomodate all iDRACs.

Detailed
Description

The starting IP address specified cannot accommodate all the servers. The starting iDRAC IPv4
Address specifies the static IPv4 address of the iDRAC located in the first slot. The static IPv4
address of each subsequent iDRAC is calculated as a slot number increment of this IPv4
address.

Recommended
Response Action

Make sure there are enough IPv4 addresses for all the iDRACs and then retry the operation.

Category

Audit

SubCategory

SWC = Software Config

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE