Enc13, Enc14 – Dell PowerEdge VRTX User Manual

Page 218

Advertising
background image

Trap/EventID

4339

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC13

Message

Unsupported configuration detected on

arg1

.

arg2arg3

Arguments

arg1 =

Enclosure Name

arg2 =

EMM0 1

arg3 =

EMM1 2

Detailed
Description

An unsupported configuration was detected. The SCSI rate of the Enclosure Management
Modules (EMMs) are not the same.

Recommended
Response Action

Replace one of the EMMs with the matching SCSI rate EMM.

Category

Storage

SubCategory

ENC = Storage Enclosr

Severity

Severity 2 (Warning)

Trap/EventID

4338

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC14

Message

The number of enclosures connected on

arg1

has exceeded the maximum limit supported by the

controller.

Arguments

arg1 =

controller name

Detailed
Description

There are too many enclosures attached to the controller port. When the enclosure limit is
exceeded, the controller loses contact with all enclosures attached to the port. This is an
unsupported configuration.

218

Advertising