Psu0004, Psu0005 – Dell PowerEdge VRTX User Manual

Page 525

Advertising
background image

PSU0004

Message

The power input for power supply

arg1

is outside of range.

Arguments

arg1 =

number

Detailed
Description

The operating requirements for the power supply may be found in product documentation or on
the power supply itself.

Recommended
Response Action

Verify the input source is attached to the power supply. Verify the input power is within the
operating requirements for the power supply.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

Trap/EventID

2185

LCD Message

Power input for PSU <number> is outside of range. Check PSU cables

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0005

Message

The power input for power supply

arg1

is outside of the allowable range, but it is attached to the

system.

Arguments

arg1 =

number

Detailed
Description

The operating requirements for the power supply may be found in product documentation or on
the power supply itself.

Recommended
Response Action

Verify the input power is within the operating requirements for the power supply.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 2 (Warning)

Trap/EventID

2186

LCD Message

No LCD message display defined.

Initial Default.

LC Log

525

Advertising