Pdr35, Pdr36 – Dell PowerEdge VRTX User Manual

Page 445

Advertising
background image

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 3 (Informational)

Trap/EventID

4347

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR35

Message

The only hot spare available is a SATA disk

arg1

.

Arguments

arg1 =

PD Name

Detailed
Description

The only physical disk available to be assigned as a hot spare is using SATA technology. The
physical disks in the virtual disk are using SAS technology. Because of this difference in
technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk
fails.

Recommended
Response Action

Add a SAS disk that is large enough to be used as the hot spare and assign the new disk as a
hot spare.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR36

Message

The only hot spare available is a SAS disk

arg1

.

Arguments

arg1 =

PD Name