IOV108

Message

Power fault detected on PCIE device

arg1

in

arg2arg3

.

Arguments

arg1 =

device name

arg2 =

slot type

arg3 =

slot number

Detailed
Description

The Chassis manager detected a power fault in an adapter after the adapter was powered on.
A power fauilt may be caused a damaged adapter or an adapter whose power requirements
exceed the maximum power limits of the slot.

Recommended
Response Action

Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For
a list of supported devices, contact the service provider.

Category

System Health

SubCategory

IOV = IO Virtualization

Severity

Severity 2 (Warning)

Trap/EventID

2554

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LCD;#LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

IOV010

Message

A license is required to assign more than 2 PCIE slots to a server.

Detailed
Description

Non-licensed systems are only allowed two slots per server.

Recommended
Response Action

Import license which allows assignments of more than 2 PCIE slot per server.

Category

Configuration

SubCategory

IOV = IO Virtualization

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None