Pwr8575, Pwr8576 – Dell PowerEdge VRTX User Manual

Page 584

Advertising
background image

Recommended
Response Action

Wait for three minutes, and then retry the operation. If the issue persists, remove and reinsert
the server and wait for the iDRAC to finish restarting before retying the operation.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 1 (Critical)

Trap/EventID

8417

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8575

Message

Initated the Virtual Reseat of server

arg1

.

Arguments

arg1 =

server id

Detailed
Description

A Virtual Reseat for the server identified in the message is initiated. A Virtual Reseat is the
same as removing and inserting a server.

Recommended
Response Action

No response action is required.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8576

Message

Unable to turn on the Sleeve

arg1

after Virtual Reseat.

Arguments

arg1 =

sleeve number

584