The operating system or an application failed to communicate within the timeout period. The
system was powered down. (IPMI sensor type code 23h offset - 02h event 3:0 - 4h)

Recommended
Response Action

Check the operating system, application, hardware, and system event log for exception events.

Category

System Health

SubCategory

ASR = Auto Sys Reset

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

ASR0104

Message

The OS watchdog timer powered cycle the system.

Detailed
Description

The operating system or an application failed to communicate within the timeout period. The
system was powered cycled. (IPMI sensor 23h offset - 03h event 3:0 - 4h)

Recommended
Response Action

Check the operating system, application, hardware, and system event log for exception events.

Category

System Health

SubCategory

ASR = Auto Sys Reset

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

ASR0105

Message

The OS watchdog timer powered off the system.

Detailed
Description

The operating system or an application failed to failed to communicate within the timeout
period. The system was powered off. (IPMI sensor type code 23h offset - 02h event 3:0 - 4h)

Recommended
Response Action

Check the operating system, application, hardware, and system event log for exception events.