Response Action

No response action is required. Make sure there are enough PSUs to support redundancy at
the specified power budget.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8509

Message

Unable to change the server power priority because Server Based Power Management mode
is enabled.

Detailed
Description

Unable to change the server power priority because Server Based Power Management mode
is enabled.

Recommended
Response Action

The server power priority can be changed once Server Based Power Management mode is
disabled. Using the CMC Web UI, navigate to the Chassis Overview > Power > Configuration
page, then uncheck the Enable Server Based Power Management checkbox. Retry the
operation.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8510

Message

Unable to set chassis power property

arg1

.

Arguments

arg1 =

property name

553