Enc2, Enc3 – Dell PowerEdge VRTX User Manual

Page 212

Advertising
background image

Severity

Severity 3 (Informational)

Trap/EventID

4339

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC2

Message

arg1

was removed..

Arguments

arg1 =

Enclosure Management Module Name

Detailed
Description

An Enclosure Management Module (EMM) was removed.

Recommended
Response Action

Reinsert the Enclosure Management Module (EMM). See the storage hardware documentation
for information on replacing the EMM.

Category

Storage

SubCategory

ENC = Storage Enclosr

Severity

Severity 1 (Critical)

Trap/EventID

4337

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC3

Message

arg1

is shutdown.

Arguments

arg1 =

Enclosure Name

Detailed
Description

The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable
temperature range.

Recommended
Response Action

Check for factors that may cause overheating or excessive cooling. For example, verify that the
enclosure fan is working. You should also check the thermostat settings and examine whether
the enclosure is located near a heat source. Make sure the enclosure has enough ventilation
and that the room temperature is not too hot or too cold. Refer to the enclosure documentation
for more diagnostic information.

212