Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

IOV1004

Message

Too many slots provided as parameters to Assign and UnAssign Servers methods.

Detailed
Description

The parameters for the method identified in the message are not passed correctly.

Recommended
Response Action

Refer to the Dell Chassis PCI Management Profile document and provide the required
parameters.

Category

Configuration

SubCategory

IOV = IO Virtualization

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

IOV1005

Message

Invalid slot FQDD

arg1

.

Arguments

arg1 =

FQDD value

Detailed
Description

The FQDD (Fully Qualified Device Descriptor) entered for the operation does not map to any
instance of the DCIM_ChassisPCISlot class.

Recommended
Response Action

Perform the Enumerate operation on the DCIM_ChassisPCISlot class to determine the the
correct FQDD value for the required slot. Retry the operation with the correct FQDD value.

Category

Configuration

SubCategory

IOV = IO Virtualization

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

313