Pci event messages, Pci1300, Pci1302 – Dell PowerEdge VRTX User Manual

Page 403: 24 pci event messages

Advertising
background image

24

PCI Event Messages

PCI1300

Message

A front panel diagnostic interrupt was detected.

Detailed
Description

The front panel diagnostic was pressed, and the system may be halted as a result. The
interrupt was user induced.

Recommended
Response Action

Reset the system to continue operation.

Category

System Health

SubCategory

PCI = PCI Device

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PCI1302

Message

A bus time-out was detected on a component at bus

arg1

device

arg2

function

arg3

.

Arguments

arg1 =

bus

arg2 =

device

arg3 =

func

Detailed
Description

System performance may be degraded. The device has failed to respond to a transaction
(master/target abort or completion timeout).

Recommended
Response Action

Cycle input power, update component drivers, if device is removable, re-install the device.

Category

System Health

SubCategory

PCI = PCI Device

Severity

Severity 1 (Critical)

403