Cmc8517, Cmc8518 – Dell PowerEdge VRTX User Manual

Page 113

Advertising
background image

SubCategory

CMC = Chassis Management Controller

Severity

Severity 2 (Warning)

Trap/EventID

2546

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8517

Message

A double height server is detected in slot

arg1

, however the server is not detected in the bottom

slot.

Arguments

arg1 =

slot number

Detailed
Description

A double height server is detected in slot specified in the message, however the server is not
detected in the bottom slot. This occurs if the server is not correctly inserted into the chassis.

Recommended
Response Action

Remove the server from the chassis, check for any broken or bent pins at the rear of the
server. If there is no damage, reinsert the server into the chassis.

Category

System Health

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

2545

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8518

Message

Detecting Double height server in slot

arg1

but the iDRAC in bottom slot

arg2

is also responding.

Arguments

arg1 =

slot number

arg2 =

slot number

Detailed
Description

the Double height server identified in the message is detected in the top slot. However, the
bottom slot is also responding which should not occur if a double height server is inserted.