Pci1342, Pci1344 – Dell PowerEdge VRTX User Manual

Page 409

Advertising
background image

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PCI1342

Message

A bus time-out was detected on a component at slot

arg1

.

Arguments

arg1 =

number

Detailed
Description

System performance may be degraded. The device has failed to respond to a transaction
(master/target abort or completion timeout).

Recommended
Response Action

Cycle input power, update component drivers, if device is removable, re-install the device.

Category

System Health

SubCategory

PCI = PCI Device

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PCI1344

Message

An I/O channel check error was detected.

Detailed
Description

None

Recommended
Response Action

Cycle input power, update component drivers, if device is removable, re-install the device.

Category

System Health

SubCategory

PCI = PCI Device

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

An I/O channel check error detected. Power cycle system.

Initial Default.

FALSE

409