Cmc8511 – Dell PowerEdge VRTX User Manual

Page 110

Advertising
background image

Detailed
Description

This happens during promotion of extended storage feature from single CMC to dual CMC. If
the media on Standby CMC is not healthy, this message is displayed and the feature returns to
single CMC state.

Recommended
Response Action

Do one of the following, and retry the operation: 1) In the CMC Web interface, go to Chassis
Controller > Flash Media > Configuration and verify if the card on the secondary CMC displays
some errors. 2) Do a failover and then reprovision the card from the same GUI page.
Reprovisioning is only allowed on the card of primary CMC. However, if both the options 1 and
2 fail, the card may be no longer functional.

Category

Audit

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

8689

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8511

Message

Unable to synchronize the data in the Extended Storage removable flash media in the primary
and secondary CMCs.

Detailed
Description

The data on the Extended Storage removable flash media SD cards is not synchronized when
the CMC is unable to determine which card has the latest data.

Recommended
Response Action

Disable and then enable the Extended Storage feature. Using racadm, executure the following
commands: "racadm feature -d -c Extended Storage" to disable and then "racadm -a -c
Extended Storage" to enable the feature. NOTE: All the data on the removable flash media SD
card is erased when the feature is disabled.

Category

Audit

SubCategory

CMC = Chassis Management Controller

Severity

Severity 2 (Warning)

Trap/EventID

8690

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

110

Advertising