background image

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8505

Message

Unable to access server:

arg1

because both IPv4 and IPv6 are disabled. NIC Enabled =

arg2

.

Arguments

arg1 =

slot number

arg2 =

state

Detailed
Description

IPv4 and IPv6 are disabled on the specified server and the CMC is unable to display the link to
launch iDRAC web interface.

Recommended
Response Action

Enable IPv4 or IPv6 for the specified server using the CMC command line or CMC Web GUI
interface, so that the link to launch iDRAC is displayed on the CMC Web interface. To enable
the NIC for DHCP using RACADM, enter "racadm setniccfg -m server-<slot number> -d" where
<slot number> is the server identifed in the message. To enable the NIC using the Web
interface, click Server Overview > select the identified server, go to Setup > select the Enable
IPv4 check box and/or the Enable IPv6 check box.

Category

System Health

SubCategory

CMC = Chassis Management Controller

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8506

Message

A command to shut down the CMC was initiated.

Detailed
Description

A command to shut down the CMC was initiated.

Recommended
Response Action

No response action is required.

Category

Audit

107