Pdr44, Pdr46 – Dell PowerEdge VRTX User Manual

Page 450

Advertising
background image

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR44

Message

The clear operation on

arg1

failed.

Arguments

arg1 =

physical disk

Detailed
Description

A Clear task was being performed on a physical disk but the task was interrupted and did not
complete successfully. The controller may have lost communication with the disk, the disk was
removed, or the cables may be loose or defective.

Recommended
Response Action

Verify that the disk is present and not in a Failed state. Make sure the cables are attached
securely. See the storage hardware documentation for more information on checking the
cables. Restart the Clear task.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 1 (Critical)

Trap/EventID

4345

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR46

Message

Patrol Read found an uncorrectable media error on

arg1

.

Arguments

arg1 =

physical disk

Detailed
Description

The Patrol Read task has encountered an error that cannot be corrected. There may be a bad
disk block that cannot be remapped.

Recommended
Response Action

Backup your data from the disk. Start disk initialization and wait for it to complete, then restore
the data from the backup to the disk.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 1 (Critical)

450