Stor5, Stor6 – Dell PowerEdge VRTX User Manual

Page 715

Advertising
background image

Severity

Severity 1 (Critical)

Trap/EventID

4177

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

STOR5

Message

Redundancy lost.

arg1

Arguments

arg1 =

VD/Enclosure Name

Detailed
Description

A virtual disk or enclosure has lost data redundancy. In the case of a virtual disk, one or more
physical disks included in the virtual disk have failed. Due to the failed physical disk or disks,
the virtual disk is no longer maintaining redundant (mirrored or parity) data. The failure of an
additional physical disk will result in lost data. In the case of an enclosure, more than one
enclosure component has failed. For example, the enclosure may have suffered the loss of all
fans or all power supplies.

Recommended
Response Action

Identify and replace the failed components. To identify the failed component, select the
Storage object and click the Health subtab. The controller status displayed on the Health
subtab indicates whether a controller has a failed or degraded component. Click the controller
that displays a Warning or Failed status. This action displays the controller Health subtab
which displays the status of the individual controller components. Continue clicking the
components with a Warning or Failed status until you identify the failed component. See
Storage Health for more information. See the enclosure documentation for information on
replacing enclosure components and for other diagnostic information.

Category

Storage

SubCategory

STOR = Storage

Severity

Severity 2 (Warning)

Trap/EventID

4178

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

STOR6

Message

CEM Storage Management detected inventory change(s) after host re-boot.