Vdr8 – Dell PowerEdge VRTX User Manual

Page 861

Advertising
background image

Detailed
Description

One or more physical disks included in the virtual disk have failed. If the virtual disk is non-
redundant (does not use mirrored or parity data), then the failure of a single physical disk can
cause the virtual disk to fail. If the virtual disk is redundant, then more physical disks have
failed than you can rebuild using mirrored or parity information.

Recommended
Response Action

Create a new virtual disk and restore from a backup.

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 1 (Critical)

Trap/EventID

4353

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR8

Message

arg1

has become degraded.

Arguments

arg1 =

virtual disk

Detailed
Description

This message occurs when a physical disk in the disk group was removed or when a physical
disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses
mirrored or parity information) and only one physical disk has failed, the virtual disk can be
rebuilt.

Recommended
Response Action

Configure a hot spare for the virtual disk if it is not already configured. Rebuild the virtual disk.
If a physical disk was removed from the disk group, either replace the disk or restore the
original disk.

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 2 (Warning)

Trap/EventID

4354

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

861