Bat1009, Bat1010 – Dell PowerEdge VRTX User Manual
Page 76
Trap/EventID
4274
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
BAT1009
Message
Write policy on
arg1
was changed to Write Back.
Arguments
•
arg1 =
controller name
Detailed
Description
The controller battery health has returned to normal.
Recommended
Response Action
No response action is required.
Category
Storage
SubCategory
BAT = Battery Event
Severity
Severity 3 (Informational)
Trap/EventID
4275
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
BAT1010
Message
Battery on
arg1
requires reconditioning. Initiate a learn cycle.
Arguments
•
arg1 =
Controller name
Detailed
Description
Battery is in warn only mode and requires reconditioning.
Recommended
Response Action
Start a learn cycle on the battery.
Category
Storage
SubCategory
BAT = Battery Event
76