Psu8505, Psu8506 – Dell PowerEdge VRTX User Manual

Page 511

Advertising
background image

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU8505

Message

Unable to set the chassis redundancy policy to AC Redundancy.

Detailed
Description

Unable to set the chassis redundancy policy to AC Redundancy.

Recommended
Response Action

Retry the operation using the CMC command line interface or CMC Web interface. To set the
chassis redundnacy policy using the command line, enter "racadm config -g cfgChassisPower -
o cfgChassisRedundancyPolicy 1". To configure the chassis redundancy policy using the Web
interface, click Chassis Overview > Power > Configuration. From the Redundancy drop-down
menu, select AC Redundancy.

Category

Audit

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU8506

Message

Unable to change power cap because Server Based Power Management Mode is enabled.

Detailed
Description

When the Server Power Management mode is enabled the Power cap cannot be set.

Recommended
Response Action

To enable the ability to set the power cap, switch to external Power Management and disable
the Server Based Management Mode in the CMC Web interface.

Category

Audit

SubCategory

PSU = Power Supply

Severity

Severity 2 (Warning)