Vdr19, Vdr20 – Dell PowerEdge VRTX User Manual

Page 867

Advertising
background image

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 1 (Critical)

Trap/EventID

4353

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR19

Message

Reconfiguration of

arg1

has failed.

Arguments

arg1 =

virtual disk

Detailed
Description

The reconfiguration operation was not completed. This may be due to a user action or a
physical disk failure.

Recommended
Response Action

Recreate the virtual disk and restore data from a backup copy.

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 1 (Critical)

Trap/EventID

4353

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR20

Message

arg1

rebuild failed.

Arguments

arg1 =

VD Name

Detailed
Description

A physical disk included in the virtual disk has failed or is corrupt. You may also have cancelled
the rebuild.

867