Psu0019 – Dell PowerEdge VRTX User Manual
Page 524
Arguments
•
arg1 =
number
Detailed
Description
The power supply is installed correctly but an input source is not connected or is not
functional.
Recommended
Response Action
Verify the input source is attached to the power supply. Verify the input power is within the
operating requirements for the power supply.
Category
System Health
SubCategory
PSU = Power Supply
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Power input for PSU <number> is lost. Check PSU cables
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PSU0019
Message
The input power for power supply
arg1
has been restored.
Arguments
•
arg1 =
number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category
System Health
SubCategory
PSU = Power Supply
Severity
Severity 3 (Informational)
Trap/EventID
2187
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
524