Enc27, Enc28 – Dell PowerEdge VRTX User Manual

Page 225

Advertising
background image

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC27

Message

SAS or SATA mixing of physical disks is not supported within the

arg1

.

Arguments

arg1 =

Enclosure Name

Detailed
Description

The enclosure cannot support both SAS and SATA physical disks. Physical disks may be
disabled. This alert is provided for informational purposes.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

ENC = Storage Enclosr

Severity

Severity 3 (Informational)

Trap/EventID

4339

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC28

Message

Enclosure Management Module (EMM) firmware version mismatch detected in

arg1

.

arg2arg3

.

Arguments

arg1 =

enclosure name

arg2 =

EMM 0 version

arg3 =

EMM 1 version

Detailed
Description

The firmware on the EMM modules is not the same version. Both modules must have the same
firmware version. This message is caused when you attempt to insert an EMM module that has
a different firmware version than an existing module.

Recommended
Response Action

Upgrade to the same version of the firmware on both EMM modules.

Category

Storage

SubCategory

ENC = Storage Enclosr

225