Pwr8573, Pwr8574 – Dell PowerEdge VRTX User Manual

Page 583

Advertising
background image

SubCategory

PWR = Power Usage

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8573

Message

The Chassis Management Controller is unable to communicate to the iDRAC, when trying to
turn off the server

arg1

.

Arguments

arg1 =

server id

Detailed
Description

The Chassis Management Controller is not able to communicate with the iDRAC on the server
identified in the message. Therefore the server could not be turned off. This situation may
occur when iDRAC is restarting.

Recommended
Response Action

Wait for three minutes, and then retry the operation. If the issue persists, remove and reinsert
the server and wait for the iDRAC to finish restarting before retying the operation.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

Trap/EventID

8418

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8574

Message

The Chassis Management Controller is unable to communicate to the iDRAC, when trying to
hard reset the server

arg1

.

Arguments

arg1 =

slot number

Detailed
Description

The Chassis Management Controller is not able to communicate with the iDRAC on the server
identified in the message. Therefore the server could not be hard reset. This situation may
occur when iDRAC is restarting.

583