VLT Event Messages

VLT0300

Message

CPU

arg1arg2

voltage is less than the lower warning threshold.

Arguments

arg1 =

number

arg2 =

name

Detailed
Description

Low voltages may be the result of a problem with the voltage regulator or a problem with the
processor. The low voltage may cause the processor to fail to operate.

Recommended
Response Action

1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

VLT = Voltage

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

VLT0301

Message

CPU

arg1arg2

voltage is less than the lower critical threshold.

Arguments

arg1 =

number

arg2 =

name

Detailed
Description

Low voltages may be the result of a problem with the voltage regulator or a problem with the
processor. When the critical threshold is crossed, the processor will fail to operate. The
system may power down.

Recommended
Response Action

1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.