Cpu0802, Cpu0803 – Dell PowerEdge VRTX User Manual

Page 149

Advertising
background image

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

CPU0802

Message

A predictive failure detected on CPU

arg1

voltage regulator module.

Arguments

arg1 =

number

Detailed
Description

System performance may be degraded or the system may fail to operate.

Recommended
Response Action

1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

CPU = Processor

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

CPU0803

Message

The power input for CPU

arg1

voltage regulator module is lost.

Arguments

arg1 =

number

Detailed
Description

System performance may be degraded or the system may fail to operate.

Recommended
Response Action

1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.

149