Pdr57 – Dell PowerEdge VRTX User Manual

Page 456

Advertising
background image

Detailed
Description

The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk
blocks are remapped. When the table is full, bad disk blocks are no longer remapped, which
means that disk errors are no longer corrected. At this point, data loss can occur. The bad
block table is now 80 percent full.

Recommended
Response Action

Replace the disk generating this message.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR57

Message

Bad block table on

arg1

is full. Unable to log block

arg2

.

Arguments

arg1 =

physical disk

arg2 =

logical block address

Detailed
Description

The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk
blocks are remapped. When the table is full, bad disk blocks are no longer remapped, which
means that disk errors are no longer corrected. At this point, data loss can occur.

Recommended
Response Action

Replace the disk generating this message and restore from a backup copy. You may have lost
data.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 1 (Critical)

Trap/EventID

4345

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

456