Recommended
Response Action

Assign a larger disk as the global hot spare.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR51

Message

Hot spare

arg1

SMART polling has failed.

arg2

Arguments

arg1 =

physical disk

arg2 =

args

Detailed
Description

The controller firmware attempted to do SMART polling on the hot spare but could not
complete the SMART polling. The controller may have lost communication with the hot spare.

Recommended
Response Action

Verify the health of the disk assigned as a hot spare. Replace the disk and reassign the hot
spare. Make sure the cables are attached securely. See the storage hardware documentation
for more information on checking the cables.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 1 (Critical)

Trap/EventID

4345

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR52

Message

A redundant path is broken.

Detailed
Description

The controller has two connectors that are connected to the same enclosure. The
communication path on one connector has lost connection with the enclosure. The
communication path on the other connector is reporting this loss.