Pst0193, Pst0194 – Dell PowerEdge VRTX User Manual

Page 505

Advertising
background image

Category

System Health

SubCategory

PST = BIOS POST

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

Shut-down test failed. Power cycle system

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PST0193

Message

BIOS POST memory test failed.

Detailed
Description

System BIOS POST memory test failed. This exception occurred early in system power on, thus
the system may not display video. (BIOS POST exception code C1)

Recommended
Response Action

Compare system memory installation to supported system memory configurations. Reduce
system configuration to minimum memory configuration.

Category

System Health

SubCategory

PST = BIOS POST

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

BIOS POST memory test failed. Check memory devices

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PST0194

Message

Remote access controller configuration failed.

Detailed
Description

System BIOS could not configure the Remote Access controller This exception occurred early
in system power on, thus the system may not display video. (BIOS POST exception code C2)

Recommended
Response Action

Cycle input power and power on the system. If the problem persists, contact technical support.
Refer to the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

PST = BIOS POST

Severity

Severity 1 (Critical)

505